Inspections & Testing

When people require their electrics to be checked, they often call it different things:

What they are asking for in all these cases is an in-service, inspection and more importantly Test of their Electrical installation. This is known as only one thing in the IEE wiring regulations - a Electrical Installation Condition Report.

The IEE Wiring Regulations recommend that an Electrical Installation Condition Report should be considered for the following reasons:

  • A change of occupancy of the premises.
  • A change of use of the premises.
  • After alterations or additions to the original installation.
  • Where there is reason to believe that damage may have been caused to the installation.

The title for the Test Report Changed in 2014 under updated IEE Electrical Regulations.  It is now called an "Electrical Installation Condition Report"  (EICR) -it is aptly named as that is what it is, it gives the findings of an Electrical Installation which has been tested - It is NOT a Safety Certificate. Where works are carried out after the EICR to bring the installation up to a safe standard, then the report will give evidence of a satisfactory Installation.

What happens when an Inspection and test is carried out?

A series of visual checks ae carried out on the electrical installation.  Circuit breaker will be checked to ensure they are of the correct type and rating to protect the outgoing cable. The cables will be checked for current carrying capacity and voltage drop. Signs of damage, burning etc., will be looked for. 10% of all sockets, switches etc., are opened up and inspected. If there are any non-compliances found, then even more and probably all of the accessories are then checked.

The Inspection is followed by the tests. 100% of the installation is tested. Several electrical measurements are recorded on the report including continuity of circuit protective conductors, main and supplementary earth bonding, continuity of ring final circuit conductors, insulation resistance, polarity, earth-fault loop impedance, RCD tests including trip time in milliseconds, correct operation of switches, and isolators, protective fault current.

The installation is then declared Satisfactory or Unsatisfactory. Many installations are found to be satisfactory, but are to older regulations, and would benefit from being upgraded. If this is the case then we would advise you of the best way to comply with current standards.

Rates & Fixed Prices

Our Pricing & Rates are Transparent to all Customers. Please see Pricing

For further Information, please do not hesitate to contact us.

Telephone: 01892 531728

Email: karen@brightsparkelectrician.co.uk

Karen runs a great company. She is that very rare breed of taking care, respecting and rewarding her employees. In turn, Terry who carried out our work showed due care and attention and completed works with such professionalism. He interacted with my inquisitive little boy who may, one day may, become an electrician - he certainly had a great role.model to follow!

Marc - Sundridge

We couldn’t single out any one person as they’re all great. Joe was very helpful today and made a lovely neat job of the work. We wouldn’t use any other company. Best wishes. Carolyn

Carolyn - Sevenoaks

The guys did a great job yesterday – and were very accommodating too (putting things back in cupboards that they had to remove.) I gave them regular coffee / tea (and my wife made them a couple of Apple buns too) – and last night I gave them each a bottle of VERY good wine as a small thank you. GW - Hildenborough

You just saved us the biggest headache ever; after months of electrical problems ( now resolved), we had a ‘no power situation’. After checking circuit boards, switches etc we were at a complete loss. Read your piece above (after Googling ‘circuit board switches up, but no power‘) about RCD switch and resetting (didn’t know what an RCD was), and after 8 hours sleep dreaming of circuit boards and 2 minutes of contemplation, and re-reading your advice,I totally nailed it. Brilliant tutorial, many thanks. Susanne (I am neither young nor savvy with anything technical)

Susanne

I was very pleased with the prompt and efficient service. The electrician phoned in advance to confirm his time of arrival and was friendly and polite.

SM, Leigh

REQUEST QUOTE